EMD-1080
A 11.5 A single particle reconstruction of GroEL using EMAN.
EMD-1080
Single-particle11.5 Å
Deposition: 06/05/2004
Map released: 12/05/2004
Last modified: 26/05/2011
Concentration: 1.0
mg/mL
Vitrification
Cryogen name: ETHANE
Instrument: HOMEMADE PLUNGER
Details: Vitrification instrument: Manual, gravity, plunger
Instrument: HOMEMADE PLUNGER
Details: Vitrification instrument: Manual, gravity, plunger
Microscope: JEOL 4000EX
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: LAB6
Acceleration voltage: 400 kV
Nominal CS: 4.1 mm
Nominal defocus: 1.0 µm - 2.4 µm
Nominal magnification: 50000.0
Specimen holder model: GATAN LIQUID NITROGEN
Specimen holder details: Side entry
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: LAB6
Acceleration voltage: 400 kV
Nominal CS: 4.1 mm
Nominal defocus: 1.0 µm - 2.4 µm
Nominal magnification: 50000.0
Specimen holder model: GATAN LIQUID NITROGEN
Specimen holder details: Side entry
Image Recording
[1]
Detector category:
FILM
Detector model: KODAK SO-163 FILM
Scanner: ZEISS SCAI
Sampling interval: 7 µm
Number of real images: 5
Average electron dose per image: 30 e/Å2
Bits per pixel: 8.0
Details: Data was median filtered to 14 microns/pixel after scanning.
Detector model: KODAK SO-163 FILM
Scanner: ZEISS SCAI
Sampling interval: 7 µm
Number of real images: 5
Average electron dose per image: 30 e/Å2
Bits per pixel: 8.0
Details: Data was median filtered to 14 microns/pixel after scanning.
Details: Note that class averages are EMAN-style reference-based, not MSA.
Final
reconstruction
Resolution: 11.5
Å
(
BY AUTHOR)
Resolution method: FSC 0.5 CUT-OFF
Number of images used: 4916
Details:
Resolution method: FSC 0.5 CUT-OFF
Number of images used: 4916
Details:
⌯ Applied Symmetry
Point group:
D7
Software
[1]
Name | Version | Details |
---|---|---|
EMAN | - | - |
Final 2D classification
Number of classes:
334
CTF correction
Details:Per particle phase flipping, amplitude correction
during averaging
Format: CCP4
Data type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)
Annotation details: This is the volumetric data for our published 11.5 A resolution reconstruction of GroEL. Note that newer EMAN releases can refine the same data to ~9 A resolution.
Details: ::::EMDATABANK.org::::EMD-1080::::
Data type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)
Annotation details: This is the volumetric data for our published 11.5 A resolution reconstruction of GroEL. Note that newer EMAN releases can refine the same data to ~9 A resolution.
Details: ::::EMDATABANK.org::::EMD-1080::::
⬡ Geometry
X | Y | Z | |
---|---|---|---|
Dimensions | 100 | 100 | 100 |
Origin | -50 | -50 | -50 |
Spacing | 100 | 100 | 100 |
Voxel size | 2.7 Å | 2.7 Å | 2.7 Å |
Contour list
Primary | Level | Source |
---|---|---|
True | 0.852 | - |