EMD-2070
Octameric structure of IMPDH from Pseudomonas aeruginosa in presence of Mg-ATP
EMD-2070
Single-particle16.0 Å
Deposition: 06/04/2012
Map released: 17/04/2013
Last modified: 26/03/2014
Concentration: 1
mg/mL
Buffer
pH: 8.0
Details: 20 mM potassium phosphate pH 8 and 0.1 M KCl
Details: 20 mM potassium phosphate pH 8 and 0.1 M KCl
Grid
Details: Quantifoil R2.2, glow discharged
Vitrification
Cryogen name: ETHANE
Chamber humidity: 98%
Chamber temperature: 102.15 K
Instrument: GATAN CRYOPLUNGE 3
Method: Blot for 1 second
Chamber humidity: 98%
Chamber temperature: 102.15 K
Instrument: GATAN CRYOPLUNGE 3
Method: Blot for 1 second
Microscope: JEOL 2200FS
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 200 kV
Nominal CS: 2.0 mm
Nominal defocus: 1.4 µm - 2.5 µm
Nominal magnification: 100000.0
Calibrated magnification: 130137.0
Specimen holder model: GATAN LIQUID NITROGEN
Specimen holder details: 626 Gatan cryo-Holder
Alignment procedure: LEGACY (Astigmatism: Objective lens astigmatism was corrected at 200,000 times magnification, Electron beam tilt params: )
Details: Image acquisition is done directly on the CCD camera. It explains why the nominal magnification is 100000 and calibrated magnification 130137.
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 200 kV
Nominal CS: 2.0 mm
Nominal defocus: 1.4 µm - 2.5 µm
Nominal magnification: 100000.0
Calibrated magnification: 130137.0
Specimen holder model: GATAN LIQUID NITROGEN
Specimen holder details: 626 Gatan cryo-Holder
Alignment procedure: LEGACY (Astigmatism: Objective lens astigmatism was corrected at 200,000 times magnification, Electron beam tilt params: )
Details: Image acquisition is done directly on the CCD camera. It explains why the nominal magnification is 100000 and calibrated magnification 130137.
Temperature
Minimum: 93.15
K
Average: 95.15 K
Maximum: 96.15 K
Average: 95.15 K
Maximum: 96.15 K
Specialist optics
Energy filter
Image Recording
[1]
Detector category:
CCD
Detector model: GENERIC GATAN (4k x 4k)
Number of real images: 80
Average electron dose per image: 18 e/Å2
Details: Images directly recorded with CCD camera
Detector model: GENERIC GATAN (4k x 4k)
Number of real images: 80
Average electron dose per image: 18 e/Å2
Details: Images directly recorded with CCD camera
Details: The particles were selected using a semi-automatic selection program (Boxer).
Final
reconstruction
Resolution: 16.0
Å
(
BY AUTHOR)
Resolution method: FSC 0.5 CUT-OFF
Number of images used: 22577
Details:
Resolution method: FSC 0.5 CUT-OFF
Number of images used: 22577
Details:
⌯ Applied Symmetry
Point group:
D4
Software
[1]
Name | Version | Details |
---|---|---|
IMAGIC, FREALIGN | - | - |
CTF correction
Details:Each particle
Format: CCP4
Data type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)
Annotation details: Cryo-EM reconstruction of IMPDH from Pseudomonas Aeruginosa in presence of Mg-ATP
Details: ::::EMDATABANK.org::::EMD-2070::::
Data type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)
Annotation details: Cryo-EM reconstruction of IMPDH from Pseudomonas Aeruginosa in presence of Mg-ATP
Details: ::::EMDATABANK.org::::EMD-2070::::
⬡ Geometry
X | Y | Z | |
---|---|---|---|
Dimensions | 150 | 150 | 150 |
Origin | 0 | 0 | 0 |
Spacing | 150 | 150 | 150 |
Voxel size | 2.3 Å | 2.3 Å | 2.3 Å |
Contour list
Primary | Level | Source |
---|---|---|
True | 52.0 | AUTHOR |