EMD-2381
The structure and super-organization of acetylcholine receptor-rapsyn complexes; class C
EMD-2381
Subtomogram averaging42.0 Å
Deposition: 21/05/2013
Map released: 26/06/2013
Last modified: 03/07/2013
Buffer
pH: 7.4
Details: 400 mM NaCl, 20 mM phosphate buffer, leupeptin 0.3 mg/l, pepstatin 1 mg/l
Details: 400 mM NaCl, 20 mM phosphate buffer, leupeptin 0.3 mg/l, pepstatin 1 mg/l
Staining
Type:
NEGATIVE
Details: Unstained
Details: Unstained
Grid
Details: 300 mesh copper grid with lacy carbon support, glow discharge in amylamine atmosphere
Vitrification
Cryogen name: ETHANE
Chamber humidity: 90%
Chamber temperature: 78 K
Instrument: HOMEMADE PLUNGER
Method: blot from the carbon side
Chamber humidity: 90%
Chamber temperature: 78 K
Instrument: HOMEMADE PLUNGER
Method: blot from the carbon side
Microscope: FEI POLARA 300
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 300 kV
Nominal CS: 2 mm
Nominal defocus: 3.0 µm - 6.0 µm
Nominal magnification: 69000.0
Calibrated magnification: 80213.0
Specimen holder model: GATAN LIQUID NITROGEN
Alignment procedure: LEGACY (Astigmatism: objective lens astigmatism was corrected at 69,000 times magnification, Electron beam tilt params: )
Details: Dual tilt axis tomography
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 300 kV
Nominal CS: 2 mm
Nominal defocus: 3.0 µm - 6.0 µm
Nominal magnification: 69000.0
Calibrated magnification: 80213.0
Specimen holder model: GATAN LIQUID NITROGEN
Alignment procedure: LEGACY (Astigmatism: objective lens astigmatism was corrected at 69,000 times magnification, Electron beam tilt params: )
Details: Dual tilt axis tomography
Temperature
Minimum: 80
K
Average: 85 K
Maximum: 95 K
Average: 85 K
Maximum: 95 K
Specialist optics
Energy filter
Image Recording
[1]
Detector category:
CCD
Detector model: GATAN ULTRASCAN 4000 (4k x 4k)
Sampling interval: 15 µm
Number of real images: 142
Average electron dose per image: 50 e/Å2
Bits per pixel: 16.0
Details: Dual axis tilt series
Detector model: GATAN ULTRASCAN 4000 (4k x 4k)
Sampling interval: 15 µm
Number of real images: 142
Average electron dose per image: 50 e/Å2
Bits per pixel: 16.0
Details: Dual axis tilt series
Tilt Series
[1]
Axis 1 | Axis 2 | |||||
---|---|---|---|---|---|---|
Min. | Max. | Inc. | Min. | Max. | Inc. | Rotation |
-70 ° | 70 ° | - | - | - | - | - |
Final
reconstruction
Final 3D classification
Number of classes:
5
Final
reconstruction
Resolution: 42.0
Å
(
BY AUTHOR)
Resolution method: FSC 0.5 CUT-OFF
Algorithm: OTHER
Resolution method: FSC 0.5 CUT-OFF
Algorithm: OTHER
⌯ Applied Symmetry
Point group:
C1
Software
[1]
Name | Version | Details |
---|---|---|
XMIPP, ML, TOMO | - | - |
Final 3D classification
Number of classes:
5
Format: CCP4
Data type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)
Annotation details: Acetylcholine receptor with two pairs of rapsyn bound at approximately 72 degrees apart
Details: ::::EMDATABANK.org::::EMD-2381::::
Data type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)
Annotation details: Acetylcholine receptor with two pairs of rapsyn bound at approximately 72 degrees apart
Details: ::::EMDATABANK.org::::EMD-2381::::
⬡ Geometry
X | Y | Z | |
---|---|---|---|
Dimensions | 60 | 60 | 60 |
Origin | 0 | 0 | 0 |
Spacing | 60 | 60 | 60 |
Voxel size | 7.48 Å | 7.48 Å | 7.48 Å |
Contour list
Primary | Level | Source |
---|---|---|
True | 0.248 | AUTHOR |