EMD-5588
Electron cryo-microscopy of the yeast Mediator Cdk8 kinase module
EMD-5588
Single-particle15.0 Å
Deposition: 26/02/2013
Map released: 17/04/2013
Last modified: 15/05/2013
Concentration: 0.020
mg/mL
Buffer
pH: 7.6
Details: 20mM HEPES, 200mM potassium acetate, 5mM beta-mercaptoethanol
Details: 20mM HEPES, 200mM potassium acetate, 5mM beta-mercaptoethanol
Grid
Details: 300 mesh Cu/Rh grids with continuous carbon, glow discharged in amylamine atmosphere
Vitrification
Microscope: FEI TECNAI F20
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 120 kV
Nominal CS: 1.2 mm
Nominal defocus: 1.5 µm - 4.0 µm
Nominal magnification: 60000.0
Calibrated magnification: 60400.0
Specimen holder model: GATAN LIQUID NITROGEN
Alignment procedure: LEGACY (Astigmatism: Objective lens astigmatism was corrected at 125,000 times magnification using a CCD camera, Electron beam tilt params: )
Illumination mode: FLOOD BEAM
Imaging mode: BRIGHT FIELD
Electron source: FIELD EMISSION GUN
Acceleration voltage: 120 kV
Nominal CS: 1.2 mm
Nominal defocus: 1.5 µm - 4.0 µm
Nominal magnification: 60000.0
Calibrated magnification: 60400.0
Specimen holder model: GATAN LIQUID NITROGEN
Alignment procedure: LEGACY (Astigmatism: Objective lens astigmatism was corrected at 125,000 times magnification using a CCD camera, Electron beam tilt params: )
Temperature
Minimum: 80
K
Average: 105 K
Maximum: 110 K
Average: 105 K
Maximum: 110 K
Image Recording
[1]
Detector category:
FILM
Detector model: KODAK SO-163 FILM
Scanner: NIKON SUPER COOLSCAN 9000
Sampling interval: 6.35 µm
Number of real images: 154
Average electron dose per image: 15 e/Å2
Bits per pixel: 16.0
Detector model: KODAK SO-163 FILM
Scanner: NIKON SUPER COOLSCAN 9000
Sampling interval: 6.35 µm
Number of real images: 154
Average electron dose per image: 15 e/Å2
Bits per pixel: 16.0
Final
reconstruction
Resolution: 15.0
Å
(
BY AUTHOR)
Resolution method: FSC 0.5 CUT-OFF
Number of images used: 70000
Algorithm: OTHER
Resolution method: FSC 0.5 CUT-OFF
Number of images used: 70000
Algorithm: OTHER
⌯ Applied Symmetry
Point group:
C1
Software
[1]
Name | Version | Details |
---|---|---|
SPARX, SPIDER | - | - |
CTF correction
Details:Each particle
Format: CCP4
Data type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)
Annotation details: Map of the CDK8 kinase module including Med12, Med13, Cdk8, and CycC
Details: ::::EMDATABANK.org::::EMD-5588::::
Data type: IMAGE STORED AS FLOATING POINT NUMBER (4 BYTES)
Annotation details: Map of the CDK8 kinase module including Med12, Med13, Cdk8, and CycC
Details: ::::EMDATABANK.org::::EMD-5588::::
⬡ Geometry
X | Y | Z | |
---|---|---|---|
Dimensions | 144 | 144 | 144 |
Origin | 0 | 0 | 0 |
Spacing | 144 | 144 | 144 |
Voxel size | 2.1 Å | 2.1 Å | 2.1 Å |
Contour list
Primary | Level | Source |
---|---|---|
True | 0.00105 | EMDB |